Description
It is a 4-channel monitor that can receive input signals from a proximity eddy current sensor, a rotary position sensor (RPT), a DC linear variable differential transformer (DCLVDT), an AC linear variable differential transformer (AC LVDT), and a rotary potentiometer. The measurement type and associated sensor input will determine which input/output (I/O) modules are required. It processes the input signal and compares the processed signal with the user-programmable alarm settings. Using 3500 frame configuration software, 3500/45 can be programmed to complete the following functions:
Axial (lateral) position
Differential expansion
Standard single slope differential expansion
Non-standard single slope differential expansion
Double inclined plane differential expansion
Compensated differential expansion

Shell bulge
Valve position
Note: The monitor channels are programmed in pairs, and the above two functions can be completed at most each time. Channels 1 and 2 can fulfill one function, while channels 3 and 4 can fulfill another (or the same) function. However, only channels 3 and 4 can realize shell expansion monitoring.
The main functions of the 3500/45 monitor are:
1) Continuously compare the monitored parameters with the set alarm points and drive the alarm to provide mechanical protection
2) Provide basic machine information for operators and maintenance personnel. According to the configuration, each channel can process the input signal into a variety of parameters called “proportional value”. Each effective ratio value can be configured as an alarm setpoint, and any two effective ratio values can be configured as a dangerous set point.
When troubleshooting through LEDs, the 3500/45 is similar to the 3500/40M mentioned earlier. Sensor buffer output: There is a coaxial connector for each channel on the front panel of the monitor. Each coaxial connector has short-circuited protection. When using DC LVDT, channel 3 and channel 4 are -10Vdc level conversion. When ACLVDT is used, all channels are the DC display of the AC signal returned by the LVDT.

We Also Handle
| ABB | Honeywell | Allen Bradley | Siemens | Siemens |
| 07DC92 GJR5251600R0202 | 51309204-125 | 1756-TBCH | 6ES5951-7LD21 | 6ES5951-7LD21 |
| 07KT97D GJR5253000R0272 | MU-TAIH62 | 1762-IQ8OW6 | 6AV3627-1QL00-0AX0 | 6AV3627-1QL00-0AX0 |
| DATX110 3ASC25H209 | 51401286-100 | 1768-M04SE | QLCCM22AAN 16418-31 | QLCCM22AAN 16418-31 |
| DSBC 110 | CC-PFB401 | 1756-IF4FXOF2F | 39VIMCCN | 39VIMCCN |
| 07KT98 WT98 GJR5253100R0278 | TC-PRR021 | 1761-NET-AIC | 6DD1600-0AK0 | 6DD1600-0AK0 |
| PAB02 P70870-4-0369059 369059A10 | 10102/2/1 | 1747-M12 | 6GK1143-0TA00 | 6GK1143-0TA00 |
| TPC-1570H 3BHE031734R1011 | 51304489-100 | 1762-OB16 | 6DD1660-0AE0 | 6DD1660-0AE0 |
| 07KT93 | 8C-TAIXA1 | 1756SC-IF8H | 6DR2100-5 | 6DR2100-5 |
| DSQC532B 3HAC023447-001 | 8C-PDILA1 | 1764-LRP | 6QN5501-0BA | 6QN5501-0BA |
| SPGU240A1 SPGU 240 A1 | MC-TAMT03 | 190E-MNZ242-CB40X | 6AV6643-0BA01-1AX0 | 6AV6643-0BA01-1AX0 |
| COMMANDER 100 | CC-TAIX11 | 1769-L35CR | CTI2572 | CTI2572 |
| SNAT 4041 | 10209/2/1 | 1746-OB32E | 6DR2004-1A | 6DR2004-1A |
| 086364-001 | MC-TAIL02 | 1785-KA | 6DD1606-1AA0 | 6DD1606-1AA0 |
| CMA131 | 51405040-175 | 1747-SDN | 6ES7400-1TA01-0AA0 | 6ES7400-1TA01-0AA0 |
| DSQC355 | 8C-TDODA1 | 1756-N2 | 3-424-2283A02 | 3-424-2283A02 |
| 3HAC024322-001/01 | 900C72R-0100-44 | 1771-OWNA | 7TM3401-3/CC | 7TM3401-3/CC |
| 07KT97B GJR5253000R0277 | CC-TDOR01 | 1756-CNB | 6DD3460-0AC0 | 6DD3460-0AC0 |
| 07DC91 GJR5251400R0202 | 8C-PAONA1 | 1788-CNET | 6GK7343-1EX30-0XE0 | 6GK7343-1EX30-0XE0 |
| CS300E PAC 031-1053-00 | CC-TAON11 51306521-175 | 1756-CN2R | 6ES7331-1KF02-0AB0 | 6ES7331-1KF02-0AB0 |
| CM572-DP 1SAP170200R0001 | 51304487-150 | 1756-IM16I | C79-458-L7000-B315 | C79-458-L7000-B315 |