product description:
The ACC-5595 is a hub that operates the 5565 series of real-time reflective memory network products together with the GE intelligent platform. Reflective memory hubs can automatically bypass ports when they detect signal loss or effective loss synchronization modes, allowing nodes in other networks to remain operational.
Because the optical port is implemented using small-sized pluggable (SFP) transceivers, only the required port filling is needed. Can the ACC-5595 SFP optical module be a combination of multiple modes (short range) or a single-mode (long range) transceiver? This feature allows for cost savings and system optimization in small networks. For larger networks, several ACC-5595 components can be cascaded, allowing the managed hub array to have up to 256 nodes at most. Each port regenerates the serial optical signal, eliminating the problems of insertion loss and cable attenuation. Signal regeneration also reduces jitter. The RS232 port enables you to monitor and control your reflected memory network through a simple PC serial port. The Ethernet port function allows you to monitor and control the hub from a long distance through a local area network (LAN) or via a Web browser.

Optional configuration: ACC-5595 as a 19-inch 1U rack-mounted chassis or as a desktop chassis. The power supply of the universe almost allows any operation to meet international power standards.
The ACC-5595 automatically bypasses ports when the mode is detected when there is no effective synchronization. Three leds, adjacent to each port, provide a visual indication of the port status. Other status indications and operation methods can be obtained through
Whether it is a serial port or an Ethernet port. The status information includes detecting the installed transceiver, detecting the signal (light), detecting the effective synchronization mode and the port operation speed (2 Gb/s). The control register allows channels

Bypass is based on the absence of one or more effective synchronization modes. Bypass can also be based solely on the loss of signal (light).
In addition, each port can be manually forced to be active or bypassed regardless of the status indicators. An additional control register allows the transmitter of any port to be manually disabled.

Immediate delivery is available.
| BENTLY 1900/65A-01-02-01-00-00 | MOTOROLA VME172PA-652SE | LENZE EPL-10200-XX |
| BENTLY 1900/65A 167699-02 | SIEMENS 1FK7101-5AF71-1DG0 | BENTLY 125760-01 |
| RAMIX PMC661J | SIEMENS 1FK7080-5AF71-1FH0 | BENTLY 3500/42M 140734-02 |
| SBS PMC-HS-SERIAL | A-B 1407-CGCM/D | GE 8502-BI-DP |
| EMERSON SLS1508 KJ2201X1-BA1 | ABB SM811K01 | REXROTH DKC02.3-040-7-FW |
| MOTOROLA MVME2400 | JUMO ATH-SW-22 | REXROTH DKC02.3-100-7-FW |
| ABB CI855K01 | ABB REM545BM222BAAA | HELMHOLZ 700-872-MDM02 |
| GE IS420ESWBH1A | ZYGO ZMI-2002 8020-0211-1-J | Bently 3500/50 133442-01 |
| EPRO PR6426/010-010+CON021 | ABB TB852 3BSC950263R1 | GE TP2020SS RMS-9 |
| A-B 2711-K10C20/E | Kollmorgen E33NCHA-LNN-NS-00 | ABB PP865A |
| ABB 3HAB8101-18/09A | UE LDP1WC/250P-16 | BENTLY 125680-01 |
| EPRO PR9268/200-000 | ABB TP857 3BSE030192R1 | SIEMENS SIMATIC FIELD PG M4 |
| Rolls-Royce SLIO 02 | ABB PP865A 3BSE042236R2 | EPRO PR6423/010-040+CON021 |







There are no reviews yet.