Description
The Bently Nevada 330101-00-18-10-02-05 is a high-performance proximity probe designed for accurate and reliable vibration monitoring. It is a non-contact measurement system, ideal for detecting vibration and displacement in industrial machinery.
Specifications
- Unthreaded Length Option: 0.0 inches
- Overall Case Length Option: 1.8 inches
- Total Length Option: 1.0 meter (3.3 feet)
- Connector and Cable-Type Option: Miniature coaxial ClickLoc™ connector with standard cable
- Agency Approval Option: CSA, ATEX, IECEx Approvals
- Shipping Weight: 5 kg
Key Features
- Non-Contact Vibration Measurement: Designed for accurate proximity sensing of machinery vibration without physical contact.
- High-Quality Connectors: Equipped with Miniature coaxial ClickLoc™ connectors for reliable signal transmission.
- Approved for Hazardous Locations: Meets CSA, ATEX, and IECEx standards, making it suitable for use in hazardous environments.
- Durable Construction: Built to withstand harsh industrial environments for long-term operation.

Modular Design
Half-height, dual-channel structure: Saves frame space and supports flexible expansion.
Building-block architecture: Compatible with other modules of the 3300 system (such as power supply, system monitor), allows on-site expansion of frame size, and reduces long-term usage costs.
Anti-interference Capability
Optimized filtering algorithm: Can accurately identify signals even in strong electromagnetic interference environments (such as power plants, petrochemical workshops).
Low-speed support: Can generate phase-locked pulses stably even in low-speed or mechanical noise scenarios.
Redundancy and Reliability
Main-standby dual-module parallel: Supports dual-module redundant configuration to avoid single-point failure risks.
Triple-module redundancy (TMR) compatibility: In the TMR architecture, two phase-locked modules can work collaboratively to provide dual-phase signal guarantee.
Self-check and Diagnosis
Real-time status monitoring: Directly displays the operating status through front-panel LED lights (OK/TX/RX/channel alarm).
Fault warning: When a probe open circuit, short circuit or signal out of range is detected, it immediately triggers system event recording and activates alarm logic.

| EPRO PR9268/200-000 | IBA ibaFOB-4i-S | ABB S-073N 3BHB009884R0021 |
| GE SR489-P5-LO-A20-E | ABB GFD563A101 3BHE046836R0101 | ABB 5SDF0860H0003 |
| ABB V17152-310 | MITSUBISHI HA-SC23 | VARIAN 100010078-01 |
| Pacific Scientific PC834-001-T | ORIENTAL NETC01-M2 | VARIAN 100010077-06 |
| GE VMIVME-5565 | REXROTH DKC02.3-100-7-FW | MOTOROLA MVME5500 |
| ABB 5SHY4045L0001 3BHB018162R0001 | EMERSON CE4050S2K1C0 | ABB LDGRB-01 3BSE013177R1 |
| 33VM52-000-29 | SCHNEIDER BMXAMI0800 | A-B 2094-BM01-S/C |
| MOOG D136-001-007 | FOXBORO E69F-TI2-S | SEW DRN80M4/BE1/TF |
| YASKAWA JANCD-XCP01-1 | SIEMENS 6SL3121-1TE24-5AA3 | BANNER LS4RLQ |







There are no reviews yet.