The DEIF RMP-112D is a generator control relay module produced by DEIF Company. It is specifically designed for generator and prime mover protection, and features both overload and reverse power protection functions. Here is a detailed introduction about the DEIF RMP-112D:
I. Core Functions
Overload Protection: The RMP-112D can monitor the load condition of the generator. When the load exceeds the set overload threshold (25% to 125%), the relay will act to protect the generator from overload damage.
Reverse Power Protection: In addition to overload protection, the RMP-112D also has reverse power protection functionality. When the generator experiences reverse power (i.e., the generator absorbs power from the grid instead of outputting power to the grid), and the reverse power exceeds the set reverse power threshold (0 to 25%), the relay will act to prevent the generator from being damaged.
Flexible Parameter Configuration: Users can flexibly configure the set points for overload and reverse power, as well as related action times and delay times, according to their actual needs.
Technical Features
High Reliability: Utilizing advanced hardware and software designs, it ensures the high reliability and stability of the system.
Modular Design: Facilitates system expansion and maintenance, reducing lifecycle costs.
Multiple Installation Options: Supports 35mm DIN rail or base installation, allowing users to choose according to their actual needs.
Fault Indication: Equipped with LED display function during faults, facilitating users to quickly locate and solve problems.

Advantages and Benefits
Enhance Generator Safety: Through overload and reverse power protection functions, ensure the safe operation of the generator, and reduce the risk of faults and damage.
Reduce Maintenance Costs: The modular design and fault indication function make the maintenance of the system simpler and faster, thereby reducing maintenance costs.
Strengthen System Stability: The high reliability and stability of RMP-112D help improve the stability of the entire power system, reducing power outages and faults.

Application fields
The RMP-112D is mainly applied in scenarios where generator protection is required, such as ship power management systems, industrial generator sets, backup power systems, etc. In these scenarios, the RMP-112D can ensure the safe operation of the generator, preventing equipment damage and power outages caused by overload or reverse power.