Basler BE1-25A BE125AA2F5V3D0 Automatic Synchronization Device

Brand/Manufacturer:Basler

Order Number: BE1-25A BE125AA2F5V3D0

Country of Origin: USA

Condition: Original Brand

Lead Time: Available in stock

Payment Term: 100% TT In Advance

Tag:

Product Description

Basler BE1-25A, style number BE125AA2F5V3D0, is an Automatic Synchronizer manufactured by Basler Electric for generator paralleling control. A2 stands for voltage acceptance module, F5 for frequency matching module, V3 for voltage matching module, D0 means no dead-bus module. It continuously monitors voltage, frequency and phase angle of generator and bus, automatically adjusts generator speed and voltage. When synchronizing conditions are met, it outputs breaker closing command. Settings are configured via front panel thumbwheel switches with LED status indicators. It features low burden PT sensing circuit, widely used for generator-to-bus paralleling and serves as classic spare part for power plant protection & synchronizing systems.

Specifications

Item Specification
Model BE1-25A, Style No. BE125AA2F5V3D0
Product Type Automatic Synchronizer
Option Modules A2 Voltage Acceptance; F5 Frequency Matching; V3 Voltage Matching; D0 No Dead Bus Module
Sensed Signals Voltage, Frequency, Phase Angle (single-phase sensing)
Adjustable Phase Angle Range 1°~99°
Time Delay Range 0.1~99s
Sensing Input Voltage 80~135VAC, 50/60Hz
Output Contacts Passive relay contacts, 5A@250VAC
Power Supply AC/DC universal (depends on variant)
Mounting Panel mount, S1 case
Operating Temperature -20℃ ~ +60℃
Storage Temperature -40℃ ~ +85℃
Certifications UL, IEEE C37.90, CE
Weight Approx. 6.2kg
Features Low PT burden, local front-panel setting, built-in test circuit, LED status indication

Application

  1. Thermal & hydro power plants: Automatic paralleling of steam / hydro generators, generator-to-bus breaker closing.
  2. Gas power stations & captive power plants: Paralleling of multiple generators and bus-to-bus interconnection.
  3. Oil, gas and chemical on-site power stations: Auto switch of backup generators to meet grid synchronizing safety requirements.
  4. Retrofit of legacy power plant synchronizing panels and replacement of faulty synchronizers to avoid damage caused by out-of-phase closing.

Series Models

  • BE1-25: Sync-check relay (manual synchronism supervision, non-automatic)
  • BE1-25A-A1F5V1D1: Auto synchronizer with A1, F5, V1, D1 dead bus module
  • BE1-25A-A2F5V2D1: A2, F5, V2, D1 dead bus module
  • BE1-25/79TR: Sync-check relay with auto-reclosing function
  • BE1-87: Basler generator differential protection relay




    Customers reviews

    There are no reviews yet.

    Be the first to review “Basler BE1-25A BE125AA2F5V3D0 Automatic Synchronization Device”

    Your email address will not be published. Required fields are marked *

    If you are interested in our products, or if you have trouble finding the part you need, please feel free to contact us!

    If you are purchasing these items, please let us know the part number and we will be happy to provide you with detailed information and prices. If you have prices from other suppliers, we are also willing to refer to you for discounts. You are welcome to call or email to inquire about prices and delivery dates! Free Online Quotes Email:cxdcs@foxmail.com  Whatsapp/Mobile:+86 13328779317

    Copyright © 2025-2027 shanxi runsheng import and export Co.,Ltd. all rights reserved.

    Search for products

    Back to Top
    Product has been added to your cart
    email: cxdcs@foxmail.com