Product Description
GE Multilin T60-K03-HKH-F8N-H6D-M8L-P6D-U6B is a multi-winding transformer protection, measurement & control relay from GE Vernova UR Universal Relay family. This unit adopts horizontal 19-inch rack mounting with enhanced color graphical HMI. Power supply supports 125/250V AC/DC. It is equipped with 8 CT current inputs with enhanced diagnostics, multi-channel digital inputs and Form-A relay outputs. It integrates protection, metering, fault recording, event logging and communication. It implements dual-breakpoint dual-slope percentage differential protection with inrush and overexcitation restraint plus inter-turn fault detection. It serves as primary and backup protection for medium & large power transformers. It supports IEC 61850, GOOSE and IEEE1588 time synchronization. Settings and commissioning can be done locally or remotely via EnerVista software.
Specifications
- Model: T60-K03-HKH-F8N-H6D-M8L-P6D-U6B
- Brand: GE Multilin / GE Vernova
- Type: Multi-winding Transformer Protection & Control Relay (UR Series)
- Mounting: H, Horizontal 19” rack mount
- HMI: K, Enhanced color graphical front panel
- Power Supply: H, 125/250V AC/DC universal supply
- CT/VT Module: F8N, 8 CT inputs with enhanced diagnostics
- I/O Configuration: H6D, M8L, P6D, U6B, multi digital inputs + Form-A relay outputs
- Core Protection Algorithm: Dual-breakpoint percentage differential, 2nd harmonic inrush restraint, overexcitation restraint, inter-turn fault detection
- Protection Elements: Phase distance, ground distance, phase/neutral/ground overcurrent, over/under voltage, over/under frequency, thermal overload, breaker failure protection
- Communication: Ethernet, serial port; IEC61850 Ed1/Ed2, R-GOOSE, IEEE1588 PTP, Modbus
- Additional Functions: Fault disturbance recording, SOE sequence of events, PMU synchrophasor, device diagnostics
- Operating Temperature: -40℃ ~ +85℃ wide industrial range
- Compliance: IEEE C37.91, IEC61850 certified
- Configuration Software: EnerVista UR Setup
Application
Deployed in power substations as primary and backup protection for 2-winding, 3-winding & multi-winding power transformers, autotransformers, phase regulators and reactors.
- Primary & backup differential protection for main transformers and station service transformers in power plants and substations;
- Fault detection, tripping, alarming and fault recording for transformers in transmission & distribution power grid;
- Step-up transformer protection for renewable energy farms (solar & wind power);
- Transformer protection for industrial captive power plants in metallurgy, petrochemical and water treatment industries;
- Compatible with complex substation topologies such as ring bus, breaker-and-a-half and double busbar; supports wide-area protection via R-GOOSE.
Same Series Models (UR Transformer Protection Family)
- T60-U03-HKH-F8N-H6D-M8L-P6D-U6B: T60 variant with different CPU communication module
- T35: Compact transformer management relay (UR series, cost-optimized version)
- T60-K03-HKH-F4N-H6D-M6L-P6D-U6B: T60 with 4CT for transformers with fewer windings
- T60-K03-VKH-F8N-H6D-M8L-P6D-U6B: Vertically mounted T60 variant
- 845: New generation transformer relay, successor of T60