Product Description
Model: XGF868i-2-1-OI-H-3-4-RPT-0, Baker Hughes (Panametrics) DigitalFlow XGF868i explosion-proof flare gas ultrasonic mass flow transmitter. This ordering code is 2-path configuration. Based on ultrasonic time-of-flight principle, it has no moving internal parts. It directly measures gas velocity, volumetric flow, mass flow and real-time average molecular weight, independent of gas composition variation. This unit integrates RPT pressure & temperature compensation module with OI optical interface. Equipped with Ex flameproof enclosure, designed for harsh Zone1 hazardous area, widely used for flare gas metering in refineries and offshore platforms.
Specifications
- Type: Ultrasonic flare gas mass flow transmitter
- Path Configuration: 2-path (code digit 2 = 2)
- Measurement Principle: Transit-time ultrasonic
- Velocity Range: ±0.03 ~ ±120 m/s, bi-directional measurement
- Turndown Ratio: Ultra-wide 4000:1
- Accuracy:
- Velocity: ±1.5% of reading for 2-path
- Mass Flow: ±1.9% of reading for 2-path
- Molecular Weight: ±1.8% of reading
- Pipe Size: DN350~DN3000 (14”~120”) large bore pipeline
- Media: Flare gas, vent gas; tolerant to dirty and wet gas
- Compensation: Built-in RPT real-time pressure & temperature compensation (RPT code)
- Communication & Interface: OI optical infrared interface; 4-20mA, pulse output; Modbus optional
- Explosion Protection: Ex d flameproof housing, Zone1 hazardous area certified
- Power Supply: 100–240VAC, 50/60Hz
- Operating Temp: Electronics -40℃ ~ +60℃; H high-temperature transducer option
- Pressure Drop: Zero pressure loss
- Construction: Cast aluminium explosion-proof housing, local LCD display & keypad
- Software: PanaView PC configuration software
Application
- Flare gas total flow metering and mass balance calculation for oil refineries & chemical plants
- Offshore oil & gas platform flare line vent gas measurement (Zone1 hazardous area)
- Emission gas, relief vent gas and VOC environmental emission monitoring
- Flare steam proportional control to cut steam consumption and combustion loss
- Leak detection, pipeline leak source identification and material loss reduction
- Large bore gas pipeline measurement, immunity to cross flow disturbance
Family Models
- GF868: Standard non-compact flare gas ultrasonic flowmeter (predecessor of XGF868i)
- XGF868i-1: XGF868i single-path version
- XGF868i-2: XGF868i dual-path version (base model of this unit)
- XGS868i: Ultrasonic flow transmitter for steam service
- XGM868i: General-purpose gas ultrasonic mass flow meter
- XGF868i-RPT: XGF868i variant with pressure & temperature compensation
Dimensions & Weight
- Transmitter housing: Φ230mm × 200mm height (transmitter only, excluding transducer probes)
- Net Weight (transmitter head only): approx. 11 kg
- Gross Weight complete set (transmitter + transducers + mounting hardware): approx. 22 kg
Note: Transducer probe length depends on pipe specification, weight varies with pipe size.







There are no reviews yet.