Product Description
Woodward ProTech-GII (typical part number 8237-1600) is Woodward TMR triple modular redundant overspeed protection system with IEC61508 SIL-3 certification. It works as a standalone safety trip device independent of the main turbine governor. It consists of three fully independent modules A/B/C with 2-out-of-3 voting logic. Each module accepts speed signals from MPU magnetic pickup or eddy current probes. It provides overspeed protection, over-acceleration protection and speed loss detection with fast response. It supports online testing and hot-swap module replacement, compliant with API 670. It is equipped with local LCD display, relay trip outputs, 4-20mA analog speed outputs and Modbus communication. It is widely used for safety interlock protection of gas turbines, steam turbines, hydro turbines and other critical rotating machinery.
Specifications
- Part No.: ProTech-GII (Typical PN:8237-1600)
- Brand: Woodward
- Product Type: TMR Triple Modular Redundant Overspeed Protection System
- Safety Level: IEC61508 SIL-3, meets API 670
- Architecture: Triple Modular Redundant (TMR), A/B/C three modules, 2oo3 voting logic
- Speed Input: 1 channel per module, compatible with MPU magnetic pickups, eddy current / proximity probes
- Speed Range: 0.5 ~ 32000 rpm (new firmware up to 80000 rpm for turboexpander)
- Response Time: ≤12 ms
- Power Supply Options: Dual voltage:18–32 VDC; High voltage:90–240VAC /100–150VDC
- Analog Output: 4–20mA speed transmission (3 independent channels A/B/C)
- Relays: Separate alarm relays & trip relays (configurable for individual or voted outputs)
- Communication: Modbus RTU (3 independent serial links), optional Ethernet gateway
- HMI: Front LCD, local keypad, trip & alarm event log
- Ingress Protection: IP56 (front panel mount version)
- Operating Temperature: -20℃ ~ +70℃
- Main Functions: Overspeed protection, over-acceleration protection, speed loss detection, online self-test, online module replacement, automatic sequence test
Applications
- Standalone overspeed safety protection for gas turbines and steam turbines (combined cycle power plants)
- Safety trip systems for hydro turbines, industrial compressors, turboexpanders and reciprocating engines
- SIS safety instrumented systems for turbomachinery in petrochemical plants and offshore platforms
- Hardwired safety protection for critical rotating equipment in power plants, independent from DCS and turbine governor
- Overspeed interlock for power machinery requiring SIL3 safety level and API670 compliance
ProTech Series Part Numbers
- ProTech-GII: TMR triple redundant, SIL3 overspeed protection (this model)
- ProTech-TPS: TMR triple redundant, integrated overspeed + multi-parameter safety solver, SIL3
- ProTech-SX: Simplex single module safety protection, SIL2
- ProTech-XS: Compact overspeed protection unit
- ProTech-203: Legacy TMR overspeed protection (gradually replaced by ProTech-GII)