ABB SYN 5302a-Z V277 (Order Number: 3BHB006716R0277)
I. Basic Information
Brand: ABB (Swiss original)
Series: SYNCHROTACT 5 High Precision Synchronous Auto-Grid Connection Device
Model: SYN 5302a-Z, Software Version V277
Material Code: 3BHB006716R0277
Product Type: Digital Generator Automatic Synchronous Grid Connection Device (Single Channel Grid Connection Controller)
Installation Method: Standard 19-inch rack embedded installation
Original Factory Status: In stock classic power spare parts, new original, disassembled spare parts are available for circulation. Regular warranty 12 months
Rated Voltage Specification: V277 compatible with PT secondary voltage 100V, system 50Hz grid scenario
Core Functions
Precise Synchronous Grid Connection of Generator
Real-time collection of voltage, frequency, and phase signals on the generator side and the grid side, automatically outputting acceleration/deceleration, voltage increase/voltage decrease pulse instructions, adjusting the generator speed and terminal voltage, when the voltage difference, frequency difference, and phase difference meet the set threshold, according to the inherent closing time of the circuit breaker, calculate the closing lead angle, precisely issue the closing instruction, achieving zero-impact grid connection.
Automatic + Manual Dual Modes
Full automatic one-click grid connection; also supports on-site manual voltage and frequency adjustment, single-side synchronous check, suitable for generator start-stop debugging, maintenance grid connection scenarios.
Multiple Safety Protection for Grid Connection Lockout
Directly lock the closing output when voltage exceeds limit, frequency exceeds limit, frequency difference is too large, loss of voltage, PT disconnection, to prevent non-synchronous grid connection from causing generator impact damage and grid oscillation accidents; equipped with closing timeout, multiple grid connection failures lockout protection functions.
Event Recording and Fault Alarm
Record grid connection time, synchronous parameters, tripping lockout reasons, PT abnormalities, etc. SOE events, panel LCD + status indicator lights intuitively display operation, synchronization, fault, adjustment status.
Communication Remote Transmission Function
Support Modbus, LON, Profibus bus communication, can upload grid connection status, voltage and frequency parameters, fault alarm to power plant DCS, background monitoring system, realize remote monitoring and remote switching of synchronous device.

Key Electrical Parameters
Applicable System Frequency: 50Hz (V277 version standard), compatible with 60Hz can be set by software
Voltage Input: PT secondary side AC 100V
Adjustment Output: Passive relay pulse contacts, used for governor, excitation regulator voltage and frequency adjustment
Closing Output: High-power relay contact, drives the generator main circuit breaker closing circuit
Working Power Supply: DC 24V / AC 110/220V selectable
Working Temperature: -20℃ ~ +60℃, industrial wide temperature, compliant with IEC60255 power relay equipment standard
Protection Grade: IP20 (internal installation in cabinet)

Typical Application Scenarios
Thermal power plants, hydropower stations, gas-fired power plants steam/water turbine generator sets single unit, multi-unit grid connection
Self-owned power plants, steel mills, chemical industrial parks waste heat power generation units and grid connection with the city power grid
Substation busbar segmentation, backup power automatic synchronous switching, grid tie-line grid connection operation
Distributed photovoltaic, biomass power station generator safe synchronous grid connection control






There are no reviews yet.