Product Description
TA3840R Safety Unit is an intrinsically‑safe rack of Honeywell (former Enraf) TA3840 marine tank gauging system, 19‑inch 3U rack‑mount hardware. It cannot operate standalone and must work together with TA3840R communication unit. It provides intrinsically‑safe power supply and galvanic signal isolation for EM540 radar level transmitters located in hazardous zones, forwards isolated radar signals to TA3840C main controller for level and volume calculation. DB9‑RS232 maintenance port on front panel allows direct local configuration for radar transmitters without main controller involvement. Modular slot design supports easy expansion and board replacement. Approved by major classification societies, ATEX and IECEx intrinsic‑safety certifications. This unit is discontinued by original manufacturer, available mainly as refurbished / used spare parts in aftermarket.
Technical Specifications
| Item | Specifications |
|---|---|
| Model | TA3840S Safety Unit |
| Mechanical | 19‑inch 3U standard rack; 8 slots for plug‑in boards |
| Max radar per rack | 16 radar level transmitters (2 radars per radar supply board) |
| System expansion | Max.4 pcs TA3840S under one TA3840C; total system up to 64 radars |
| Power supply | 115/230VAC,50‑60Hz; Max.100 VA power consumption |
| Operating temperature | +5℃ ~ +70℃ (installed in safe control room area) |
| Terminal wire size | Max.2.5 mm² |
| Certification | Ex ia Ga IIB / IIC; ATEX LCIE 04 ATEX 6135; IECEx LCIE 12.0008XHoneywell |
| Communication | Front DB9‑M RS232 for radar local commissioning; Backplane EMS system bus to TA3840C |
| LED indicators | Power indicator, Rx/Tx communication status LEDs |
| Status | OEM discontinued; supplied as spare parts |
Applications
- Cargo tank radar level gauging system for oil tankers, chemical tankers, product tankers
- Intrinsically‑safe power feeding and signal isolation for EM540 hazardous‑area radar transmitters
- Marine cargo tank & ballast tank level / volume monitoring system accessories
- Retrofit project & spare‑part replacement for legacy ship tank gauging system
TA3840 Series Models
- TA3840C Communication Unit: Main system controller with LCD & keypad, performs data calculation, alarm handling, Modbus / 4‑20mA output; supports up to 4 units TA3840S
- TA3840R Repeater Unit: Remote display panel for bridge / control room duplicated tank‑data display
- TA3840C A/D: Analog‑input version communication unit, for massive 4‑20mA analog sensor integration